ketorolac tromethamine injection ISECURE How Supplied/Storage and Handling

HOW SUPPLIED

Ketorolac Tromethamine Injection, USP for intramuscular and intravenous use is available in an iSecureTM single-dose sterile Syringe with Luer Lock as follows:

Unit of SaleTotal Strength/Total Volume

NDC 0409-2287-23

30 mg/mL

Carton containing 10
1 mL iSecure™ Single-Dose Syringe with Luer Lock

Store at 20 to 25ºC (68 to 77ºF). [See USP Controlled Room Temperature.] Retain in carton until time of use.

Protect from light

To Use iSecure™ Single-Dose Syringe

1. Remove green tamper evident band in a clockwise motion.1. Remove green tamper evident band in a clockwise motion.
1.
Remove green tamper evident band in a clockwise motion.
2. Depress (Push) the plunger rod. This will loosen the plunger rod that is located on the outside of the syringe barrel so that the plunger rod can be removed. This will also engage syringe.Remove the plunger rod.
2.
Depress (Push) the plunger rod. This will loosen the plunger rod that is located on the outside of the syringe barrel so that the plunger rod can be removed. This will also engage syringe.

            Remove the plunger rod.

Insert the plunger rod into the back end of the syringe barrel and turn clockwise 2 to 3 times to attach.BEFORE REMOVING LUER TIP CAP, hold the syringe with tip cap upright. Press syringe plunger until plunger moves slightly. This motion breaks the seal between plunger and syringe barrel.

Insert the plunger rod into the back end of the syringe barrel and turn clockwise 2 to 3 times to attach.

            BEFORE REMOVING LUER TIP CAP,
            hold the syringe with tip cap upright. Press
            syringe plunger until plunger moves
            slightly. This motion breaks the seal
            between plunger and syringe barrel.

3.
Twist the luer tip cap clockwise or counterclockwise to break the tamper evident label. Remove luer tip cap and discard it.

Expel the air by pushing on the plunger rod.

Attach needle or blunt cannula if required.

NOTE: To prevent needlestick injuries, needles and blunt cannulas should not be recapped, purposely bent, or broken by hand.

3.   Twist the luer tip cap clockwise or counterclockwise to break the tamper evident label. Remove luer tip cap and discard it.

This product’s labeling may have been updated. For the most recent prescribing information, please visit www.pfizer.com.

For medical information about ketorolac tromethamine, please visit www.pfizermedinfo.com or call 1‑800‑438‑1985.

Distributed by Hospira, Inc., Lake Forest, IL 60045 USA                                                                                  Hospira logo

LAB-1295-9.0

Revised: 11/2022