Medical Information
 

In order to provide you with relevant and meaningful content we need to know more about you.

Please choose the category that best describes you.

This content is intended for U.S. Healthcare Professionals. Would you like to proceed?

If you provide additional keywords, you may be able to browse through our database of Scientific Response Documents.

Our scientific content is evidence-based, scientifically balanced and non-promotional. It undergoes rigorous internal medical review and is updated regularly to reflect new information.
Not a healthcare professional? Go to the patient or caregiver website.

LINCOCIN®Other (lincomycin HCl)

To reduce the development of drug-resistant bacteria and maintain the effectiveness of LINCOCIN and other antibacterial drugs, LINCOCIN should be used only to treat or prevent infections that are proven or strongly suspected to be caused by bacteria.

PHYSICAL COMPATIBILITIES

Physically compatible for 24 hours at room temperature unless otherwise indicated.

Infusion Solutions
5% Dextrose Injection
10% Dextrose Injection
5% Dextrose and 0.9% Sodium Chloride Injection
10% Dextrose and 0.9% Sodium Chloride Injection
Ringer's Injection

1/6 M Sodium Lactate Injection
Travert 10%-Electrolyte No. 1
Dextran in Saline 6% w/v

Vitamins in Infusion Solutions
B-Complex
B-Complex with Ascorbic Acid

Antibacterial in Infusion Solutions
Penicillin G Sodium (Satisfactory for 4 hours)
Cephalothin
Tetracycline HCl
Cephaloridine
Colistimethate (Satisfactory for 4 hours)
Ampicillin
Methicillin
Chloramphenicol
Polymyxin B Sulfate

Physically Incompatible with:
Novobiocin
Kanamycin

IT SHOULD BE EMPHASIZED THAT THE COMPATIBLE AND INCOMPATIBLE DETERMINATIONS ARE PHYSICAL OBSERVATIONS ONLY, NOT CHEMICAL DETERMINATIONS. ADEQUATE CLINICAL EVALUATION OF THE SAFETY AND EFFICACY OF THESE COMBINATIONS HAS NOT BEEN PERFORMED.

Rx only

This product's label may have been updated. For current full prescribing information, please visit www.pfizer.com

Logo

LAB-0138-11.0
Revised November 2018

Did you find an answer to your question? Yes No
Did you find an answer to your question? Yes No
Didn’t find what you were looking for? Contact us.

*Contact Medical Information. 9AM-5PM ET Monday to Friday; excluding holidays.

*9AM-5PM ET Monday to Friday; excluding holidays.

Submit a medical question for Pfizer prescription products.

Report Adverse Event

Contact Pfizer Safety to report an adverse event, side effect or concern about the quality of a Pfizer product: (800) 438-1985

You may also contact the U.S. Food and Drug Administration (FDA) directly to report adverse events or product quality concerns at 1-800-FDA-1088 or www.fda.gov/MedWatch